BUILDING IN
Instructions for building-in the
appliance
Dimensions of the recess
Height of housing mm 880
Depth of housing mm 550
Width of housing mm 560
1. It is necessary that the cabinet has a ventilation
recess with the following dimensions:
Depth 50 mm
Width 540 mm
For appropriate venting, follow indications in the
figure.
50 mm
min.
cm
2
200
200 cm
2
min.
D526
540
50
560
550
880
PR 32
3. Press in the joint covers between the appliance
and the kitchen furniture.
D132
A
D022
2. Push the appliance into the housing until stop strip
(A) touches the kitchen unit.
4. Open the door and push the appliance against the
side of kitchen furniture opposite to that of
appliance hinges.
Fasten the appliance with 4 screws provided in the
kit included with the appliance. Snap vent grille (C)
and hinge cover (D) into position.
D727
C
D
5. Apply blanking covers (B) as indicated.
D013
BB
15