If the downdraught extractor is
installed beside a gas appliance, it
must only be operated in top posi-
tion and extract from the other side,
i.e. the damper closest to the gas
appliance must be closed permanent-
ly.
This can be done as follows:
1. Modifying the electronic control
system
On the PCB cut the jumper labelled
"JP01". The downdraught extractor
can now only be operated in top
position.
2. Removing a damper
To be able to mount the cover plate,
the damper has to be removed as fol-
lows:
1. Switch the downdraught extractor
on and raise it to top position.
2. Lift the top cabinet off.
3. Turn the top cabinet upside down
and put it on a soft base. Take
care not to scratch the glass on
the top.
4. Remove the two screws holding
the damper and the single screw
holding the activation arm that
closes the damper.
The damper can now be removed.
Installation beside a gas
appliance