Electrolux MGH 621 Cooktop User Manual


 
6
Overall dimensions Cut out dimensions
Width: 580 mm. Width: 550 mm.
Depth: 500 mm. Depth: 470 mm.
Engineers technical data
Instructions
for the Installer
Rear Left Burner (semi-rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Left Burner (rapid)
Heat Input 3.0 kW (10236 BTU/HR)
2.8 kW L.P.G. (9554 BTU/HR)
Rear Right Burner (semi-rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Right Burner (auxiliary)
Heat Input 1.0 kW (3412 BTU/HR)
Supply connections
Gas: RC 1/2 inch (1/2 inch male) Rear right
hand corner
Electric: 230 V ~ 50 Hz supply, 3 core flexible
cable with non rewireable plug fitted with a
3 amp cartridge fuse.
Burner Dia. Tap By-pass
1/100 mm
Auxiliary 28
Semi-rapid 32
Rapid 40
Aeration adjustment none
APPLIANCE CLASS: 3
APPLIANCE CATEGORY: II 2H3+
APPLIANCE GAS SUPPLY:
Natural gas G20 (2H) / 20mbar
Illi
This hob must be installed by qualified
personnel to the relevant British
Standards.
Any gas installation must be carried out
by a registered CORGI installer.
The manufacturer will not accept
liability, should the above instructions
or any of the other safety instructions
incorporated in this book be ignored.