12
tric supply line for the appliance. It is recommended that this
switch/circuit breaker have lockout/tagout capability. Before
making any electrical connections to this appliance, check
that the power supply is adequate for the voltage, amperage,
and phase requirements on the rating plate. The customer
also must provide a grounded electrical line cord of suitable
capacity for the input specified on the data plate.
- After making the connection and with the appliance running,
check that the rated level does not fluctuate by ± 10%.
The connection must be made with cable of a suitable for am-
perage and voltage.
The manufacturer will accept no liability for any damage or
injury resulting from the violation of the above rules or of the
current electrical safety standards in the country where the
appliance is used.
B.2.6 REVERSING OPENING OF THE DOOR
Roll-in appliances are normally supplied with opening to the
right.
When changing direction of opening so that the door opens
from left to right, proceed as follows:
• disconnect from the power supply;
• unscrew the screw in the middle of the control panel, turn the
control panel;
• unscrew the two fixing bolts from bracket “G” (Detail 1);
• remove the door and turn it through 180° and reverse the
position of the lower seal “L” (Detail 3);
• remove component “F” and fix it in place in the space pro
vided under the plastic plug on the opposite side of the door;
• remove lower bracket “E” and refit it on the opposite side
in the place provided (Detail 2);
• fix bracket “G” to the structure by screwing down the fixing
bolts;
• refit the door;
• adjust the lower seal “L” (Detail 3), using the slotted holes,
to improve door closure;
• refit the control panel;
• reconnect the power supply.
- between top of appliance and ceiling: approx. 19.7" / 500mm:
- to the sides of appliance: approx. 3.9" / 100mm;
- for door opening: approx. 30.3" / 770 mm.
- from floor to ceiling: approx. 8.5 ft / 2610mm
Should the appliance be installed in rooms where there are
corrosive substances (chlorine, etc.), it is advisable to go over
all the stainless steel surfaces with a cloth coated with vaseline
oil, in order to form a protective film.
These appliances are designed to operate at ambient
temperatures of up to 109.4°F/+43 °C.
Note: the power plug should be accessible even after having
placed the appliance in its final position for installation.
ATTENTION:
the appliance must be anchored to the floor. To anchor to the
floor, drill 4 holes, as shown in the installation diagram (see
letter Z), and use metal expansion plugs.
Z
65 23
/
64
"
1
660
m
m
23 5
/
8
"
600
m
m
24 51
/
64
"
630
m
m
34 1
/
4
"
8
7
0
m
m
30 5
/
16
"
77
0
m
m
1 31
/
32
"
50
m
m
2 61
/
62
"
7
5
m
m
3 11
/
32
"
85
m
m
2 61
/
62
"
7
5
m
m
NOTE: after anchoring the appliance to the floor, apply a sili-
cone bead on the inside of the appliance between the bottom
and the sides.
B.2.5 ELECTRICAL CONNECTION
When making the electrical connection, carefully comply with
the information on the dataplate.
The appliance works on 120V/1ph/60Hz.
CAUTION:
Connection to the electrical mains must be carried out in
accordance with current regulations and the standards re-
quired by the National Electric Code (NEC), known as NFPA 70.
Please check:
Connection to the main power must be carried out in accord-
ance with binding rules and standards.
Before connecting, make sure that:
- The line cord has an efficient grounding connection and the
main power frequency corresponds to that stated on the data
plate. If you have doubts on the efficiency of the grounding
connection have the circuit checked by a qualified technician.
- The appliance must be connected to the main power with a
permanent connection.
- In order to protect the appliance from possible overloads or
short-circuits, a fused disconnect switch or a main circuit
breaker (customer furnished) MUST be installed in the elec-
Detail 1
Detail 2
Detail 3