ELECTRICAL CONNECTION
Any electrical work required to install
this cooker should be carried out by a
qualified electrician or comp etent person, in
accordance with the current regulations.
THIS COOKER MUST BE EARTHED.
The manufacturer declines any liability
should these safety measures not be
observed.
This cooker is designed to be connected to a
240V, 50Hz AC electrical supply.
Before switching on, make sure the electricity
supply voltage is the same as that indicated on
the cooker rating plate. The rating plate is located
on the oven frame.
The cooker is supplied with a 3 core flexible
supply cord incorporating a 13amp plug fitted. In
the event of having to change the fuse, a 13amp
ASTA approved (BS 1362) fuse must be used.
Should the plug need to be replaced for any
reason, the wires in the mains lead are coloured
in accordance with the following code:
Green and Yellow
- Earth
Blue - Neutral
Brown - Live
- Connect the green and yellow (earth) wire to
the terminal in the plug which is marked with
the letter 'E' or the earth symbol or coloured
green and yellow.
- Connect the blue (neutral) wire to the
terminal in the plug which is marked with the
letter 'N' or coloured black.
- Connect the brown (live) wire to the terminal
in the plug which is marked with the letter 'L'
or coloured red.
Upon completion there must be no cuts, or stray
strands of wire present and the cable clamp must
be secure over the outer sheath of the cable.
Fuse capacity: 13A
NOTE: The earth wire should be about 2 cm
longer than the live and neutral wires.
Note:
Check on the rating plate the value for the
total connection power for establishing the
fuse power.
Before connecting check that:
fuse and household electric installation can
carry the load of the appliance (see rating
plate);
The plug used for connection is easily
accessible when the appliance is installed.
Warning
It is forbidden to route the supply cable
across the back of the oven.
Important
If the supply cable is damaged it must be
replaced by the manufacturer or its service
agent or a similarly qualified person to ensure
safety.
A cut off plug inserted into a 13 amp
socket is a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of
safety.
fig. 19
Permanent Connection
The electrical connection should be made using
a double pole isolating switch (cooker control
switch) with at least 3mm contact separation in
all poles. The cable must have conductors of
sufficiently high cross-sectional area to prevent
overheating or deterioration.
The switch must not break the yellow and green
earth cable at any point.
Ensure that the cooker supply cable
does not come into contact with surfaces
with temperatures higher than 50° C.