Electrolux RM 850GRN Cooktop User Manual


 
25
CONVERSION OF GAS
Your cooker is designed to work with natural gas,
and is convertible for use with propane or butane.
The LPG conversion kit is available from your
Service Force Centre and must be fitted by a
Corgi Registered engineer.
For changing the gas type it is necessary to:
replace the nozzles;
adjust the minimum level (simmer);
check the gas connection;
SPECIFICATION NOZZLES
Table no.1
(Cat : II
2H3+
)
Cons
Burner
Normal
power
(kW)
Economic
power
(kW)
By-
pass
(mm)
Gas Type
Pressure
(mbar)
Nozzle
diameter
(mm)
m
3
/h g/h
RAPID 2.60 0.72 0.42
Natural Gas
Butane
Propane
20 mbar
28-30mbar
37mbar
1.12
0,86
0,86
0.248
188,8
RAPID
(fish)
2.60 0.72 0.42
Natural Gas
Butane
Propane
20 mbar
28-30mbar
37mbar
1.12
0,86
0,86
0.248
188,8
SEMI-
RAPID
2.00 0.43 0.32
Natural Gas
Butane
Propane
20 mbar
28-30mbar
37mbar
0.96
0,71
0,71
0.191
145,2
AUXILIARY 1.0 0 0.3 5 0.29
Natural Gas
Butane
Propane
20 mbar
28-30mbar
37mbar
0.70
0,50
0,50
0.093
72,6
Fit the label supplied with the appliance
(in the nozzles bag) corresponding to the gas
type utilised, onto the rating plate.