Electrolux Santo 1573TK-4 Refrigerator User Manual


 
Installation
8
Your refrigerator needs air
The refrigerating unit of your refrigerator is designed for maintenance-
free operation. What it should never lack is good ventilation. Air is sup-
plied under the door through the ventilation slot between the refriger-
ator an storage surface. Air is extracted through the upper ventilation
grille. Never obstruct these openings by plinth screens or crockery.
If your refrigerator is installed
under a continuous worktop, an air
outlet opening of at least 200 cm
2
and a ventilation grille (A/B)
matching the worktop design
should be provided at the rear of
the worktop. The cut surfaces of
the worktop (C) should be var-
nished to avoid swelling due to
penetration of moisture.
The appliance wall distance must
be at least 30 mm and should be
checked before the ventilation grille is inserted.
Special accessories:
A Ventilation grille, brown
B Ventilation grille, white
Detaching the worktop
After the work-top has been removed the appliance can be installed
underneatch a continuous work-top.
The procedure is as follows:
0
Unscrew the Phillips screws (F) on
the right and the left.
0
Lift the work-top slightly, push it
about 20 mm towards the rear, and
lift it off upwards (G).
Unscrew the holding bracket (H)
and keep it in a safe place.