Elitair PN-I Ventilation Hood User Manual


 
- 14 -
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
F = AUTOMATIC STOP TIMER - 15 minutes
If your appliance does have the INTENSIVE speed function, press key E for two seconds
and it will be activated for 10 minutes after which it will return to the previously set speed.
When the function is active the LED flashes. To interrupt it before the 10 minutes have
expired press key E again.
By pressing key F for two seconds (with the hood switched off) the “clean air” function is
activated. This function switches the appliance on for ten minutes every hour at the first
speed. As soon as this function is activated the motor starts up at the first speed for ten
minutes, During this time key F and key C must flash at the same time. After ten minutes
the motor switches off and the LED of key F remains switched on with a fixed light until the
motor starts up again at the first speed after fifty minutes and keys F and C start to flash
again for ten minutes and so on. By pressing any key for the exclusion of the hood light the
hood will return immediately to its normal functioning (e.g. if key D is pressed the “clean
air” function is deactivated and the motor moves to the 2nd speed straight away. By
pressing key B the function is deactivated).
• The “automatic stop timer” delays stopping of the hood, which will continue functioning for
15 minutes at the operating speed set at the time this function is activated.
• If the apparatus is equipped with the following controls (fig.17D):
Push-button A = on/off lights switch
Push-button B = on/off cooker hood switch. The appliance switches on at speed level 1,
If the cooker hood is on depress the push-button for 2 sec. to switch off the cooker hood.
If the cooker hood is at speed level 1 it will not be necessary to depress the push-button to
switch the cooker hood off. Decreases the motor speed.
Display C = indicates the motor speed level selected and activates the timer.
Push-button D = switches on the cooker hood. Increases the motor speed. Touching the
key at 3rd speed, the intensive function runs for 10', then the appliance go back to work at
the original speed. During this function the display blinks.
Key E = The Timer times the functions on activation for 15 minutes, after which they are
switched off. The Timer is deactivated by re-pressing Key E. When the Timer is activated
the decimal point must flash on the display. The Timer cannot be activated if the intensive
speed is functioning.
The “clean air” function is activated by pressing key E for 2 seconds when the appliance
is switched off. This switches the motor on for 10 minutes every hour at the first speed.
During functioning a rotary movement of the peripheral segments must be visualised on
the display. When this time has passed the motor switches off and the fixed letter “C”
must be visualised on the display until the motor re-starts after 50 minutes for another 10
minutes and so on. Press any key apart from the light keys to return to normal functioning.
Press key E to deactivate the function.
• If the apparatus is equipped with the following controls (fig.17E):
A = LIGHT