Clearances: When facing the front of the fireplace heater the
minimum clearances to combustible construction (material) are
the following:
Open in front to provide service, access, and clearance to
construction.
Top of appliance (ceiling) 36 (inches)
Draft Diverter to Rear Wall 2 (inches)
Side Wall 6 (inches)
Heater Corners (45° angle) to Wall 4 (inches)
Floor 0 (inches)
Installation on Rugs and Tile
If this appliance is to be installed directly on carpeting, tile, or
other combustible material, other than wood flooring, the appli
-
ance shall be installed on a metal or wood panel extending the
full width and depth of the appliance.
The base referred to above does not mean the fire-proof base as
used on wood stoves. The protection is primarily for rugs that may
be extremely thick and light-color tile that can discolor.
(914mm) TOCEILING
OR HORIZONT
AL
PROJECTIONABOVE
APPLIANCE
Figure 2
Figure 3
Figure 4
CLEARANCES