Hardware Output Test Mode – Level Two
This level tests all the hardware outputs and inputs. The LCD display shows ‘HO’
Pre Finished
Integrated and Flat Door Models
Will show the following LED’s on secondary display
panel
Press POWER to skip hardware diagnostics and advance to the next level.
Press START/PAUSE to enter hardware diagnostics.
Once hardware diagnostics has been entered, letters in the LCD display indicate the current hardware output being
tested. For integrated models, the LEDs on the touch switch panel indicate the hardware output being tested, using
binary encoding, as shown in the table below.
Different combinations of outputs can be switched on or off together, but the controller will prevent components such as
the wash pump and the lid motors being turned on together.
Press START/PAUSE to advance to the next hardware output.
Press KEYLOCK to turn the currently displayed output on or off. If the bubbles symbol (green LED above start/pause
button on integrated models) is displayed, then that output has been switched on, and if it is not displayed then that
output is off.
For Phase 5.1 - the controller now monitors the power supply current when any (and only) one fill valve, detergent
diverter, water softener bypass valve, fan , rinse aid pump, water softener brine pump, wash or drain motor is turned on.
If the current is too high or too low on the component then after approx 5 seconds, the controller starts a long, low
tone repeated every second to advise the component is faulty, or disconnected. (except the water softener)
This test will not work if more than one hardware output has been turned on at the same time.
This test does not check lid motor current, as this varies too much to make useful measurements.
Press POWER to exit at any time (all outputs will be switched off on exit).