Fisher & Paykel CG365C Cooktop User Manual


 
14
Installation instructions
Converting to a different gas type
Changing the injectors
The cooktop is set to NG. A conversion kit to LP is supplied
with the cooktop.
To change the injectors, you will need a
⁄” (7 mm) box
spanner (and a ⁄” (10 mm) ring spanner for CG365D
models).
1
Turn off the cooktop and disconnect from the power
supply.
Important!
Disconnect cooktop from the power supply before continuing.
2
Make sure all gas valves are turned off.
3
Remove all grates and burner parts.
4
Unscrew the injectors (save for future use) and replace
them with the correct ones (size numbers are stamped on
the side, eg 70= 0.70 mm). See Fig. 1.
CG365D wok burner only
5
Remove the 2 screws holding each burner bowl (3
on the wok burner).
6
Lift hob tray from the product.
Important!
Beware of sharp edges.
7
Replace the wok injector with the correct
one using a
⁄” (10 mm) ring spanner.
8
Reset the venturi (see Fig. 2):
With the product isolated from the
electrical supply, ignite the burner using a
match. The flame will probably be lifting
off the burner (see Fig. 3).
Loosen the venturi securing screw. Move
the venturi towards the injector until the
flame begins to ‘yellow tip’ (see Fig. 4).
Move the venturi back until the ‘yellow tip’
just disappears (see Fig. 5)
this is the
correct venturi setting. Tighten the
securing screw.
9
To refit the hob tray, repeat steps 5 & 6 in
reverse.
10
Reset the minimum setting (see ‘Minimum
setting or turn-down’).
11
After reassembly, verify the insulation resistance
and ground continuity of the electrical circuit.
12
The label supplied with the injectors should be placed
over the existing gas type label to indicate the change.
yellow tiplifting off
good flame
venturi
Fig.1
Fig.2
Fig.3 Fig.4
Fig.5
US
CA
EN