18
INTEGRATED MODELS ONLY - INSTALLING THE FRONT PANELS
REMOVE BRACKETS FROM PRODUCT
ATTACH PANELS TO PRODUCTGROUND THE PANELS
ATTACH PANELS TO PANEL BRACKETS
16
1918
17
There must be at least
3 screws used each side
2
2
1
1
2
3
16 mm x6
Important!
Ensure the rubber seal
between the drawer
and panels is kept in
place.
Important!
Break off and discard
the tab at the top
of the Lower Panel
Bracket.
⁄” (16mm) x6
Align bottom of panels
with bottom of brackets
When refitting the
door pins,
ensure they are
orientated as shown.
3
1
1
2
Electrical Shock Hazard
Before continuing, ensure that the product is
disconnected from the power supply.
Failure to follow this warning may result in
electrical shock, injury or re.
WARNING!
Repeat for the other drawer
WARNING!
To ground (earth) the panel bracket, connect
the ground (earth) wire from the product to
one of the tabs. Any custom metal component
(e.g. handle) that extends past the rubber seal
must be grounded (earthed) too.
Failure to follow these warnings may result in
electrical shock, injury or re.
Electrical Shock Hazard
Repeat for the other drawer