Gas rate summary - NZ AU
Your Product is factory set for Natural Gas. Refer to the appropriate chart for ratings.
BURNERS NATURAL GAS LP GAS
Injector
orifice
MJ/h
@1kPa
Injector
orifice
MJ/h
@2.75kPa
Semi-Rapid (RH Front & RH Rear) 1.3 mm 8.1 MJ/h 0.80 mm 8.0 MJ/h
Auxiliary Burner (LH Front) 0.85 mm 3.5 MJ/h 0.55 mm 3.9 MJ/h
Griddle Burner (LH Rear) 1.35 mm 8.8 MJ/h 0.80 mm 8.0 MJ/h