Fisher & Paykel DI1203 Oven User Manual


 
31
Gas rate summary - EU
Your Product is factory set for Natural Gas. Refer to the appropriate chart for ratings.
DI1203DG
Griddle Burner (LH rear) Wok Burner (centre)
NG LP Gas NG LP Gas
Cat
Injector Orifice
Nominal Rating
(kW)
Injector Orifice
Nominal Rating
(kW)
Gas Rate (g/h)
Injector Orifice
Nominal Rating
(kW)
Injector Orifice
Nominal Rating
(kW)
Gas Rate (g/h)
II 2H3 +
II 2H3 B/P (30)
II 2E3 +
118 2.60 080 2.50 182 140 3.60 095 3.60 263
II 2L3 B/P (30) 118 2.40 080 2.50 182 145 3.50 095 3.60 263
II 2E3 B/P (50) 118 2.60 070 2.60 190 140 3.60 076 3.60 263
DI1203DG
Auxiliary Semi-Rapid (RH front, RH rear)
NG LP Gas NG LP Gas
Cat
Injector Orifice
Nominal Rating
(kW)
Injector Orifice
Nominal Rating
(kW)
Gas Rate (g/h)
Injector Orifice
Nominal Rating
(kW)
Injector Orifice
Nominal Rating
(kW)
Gas Rate (g/h)
II 2H3 +
II 2H3 B/P (30)
II 2E3 +
75 1.0 050 1.0 73 100 Z 2.0 073 2.15 157
II 2L3 B/P (30) 75 S 1.0 050 1.0 73 105 Z 2.0 073 2.15 157
II 2E3 B/P (50) 75 1.0 043 1.0 73 100 Z 2.0 062 2.10 153