Fisher & Paykel E522B Refrigerator User Manual


 
30
Measured Fill Calibration
The accuracy of your Measured Fill function can be affected by variations in the incoming water
pressure. The Measured Fill Calibration Mode allows you to fine-tune the amount of water
dispensed from the preselected volumes on your cabinet.
The calibration mode is worked out as a percentage. You can measure the amount the refrigerator is
under filling or over filling and increase or decrease the calibration to get the exact amount you want.
To assess whether the Measured Fill function is under or over filling:
Press the
button until 1 qt (1 L) is displayed.
Dispense this amount into a measuring jug.
Estimate the amount of water that has been dispensed into the jug.
eg. 31 floz = under filling by 1 floz or 975 ml = under filling by 25 mls
To calculate the Calibration factor:
Transfer the difference into a percentage.
eg. 32/31 = 1.03 = 103% or 1000/975 = 1.03 = 103%
Enter the Calibration mode by pressing and holding the
and buttons together for 4 seconds.
100CAL will be displayed.
The number displayed is a percentage. Adjust this accordingly using the
and buttons.
eg. 100 CAL = 103 CAL
Press the
button to confirm your selection.
Please note:
The Measured Fill function has an accuracy of +/-5% at the time of calibration.
The accuracy of your calibration will of course be subject to the accuracy of your measuring
device and method.
Calibration quick reference guides
US
Actual amount of
water received
Under filled
Difference from
32 floz
Adjust display to read
(calibration factor)
Underfilling – you dispense 1 qt but the amount of water you receive is actually less than 1 qt
31 floz 1 floz 3% 103 CAL
30 floz 2 floz 7% 107 CAL
Overfilling – you dispense 1 qt but the amount of water you receive is actually more than 1 qt
33 floz 1 floz 3% 97 CAL
34 floz 2 floz 6% 94 CAL
Metric
Actual amount of
water received
Under filled
Difference from
1 L
Adjust display to read
(calibration factor)
Underfilling – you dispense 1 L but the amount of water you receive is actually less than 1 L
975 ml 25 ml 3% 103 CAL
950 ml 50 ml 5% 105 CAL
Overfilling – you dispense 1 L but the amount of water you receive is actually more than 1 L
1025 ml 25 ml 2% 98 CAL
1050 ml 50 ml 5% 95 CAL
Measured Fill Calibration