Setting the burner minimum
Check whether the flame spreads to all
burner ports when the burner is lit with
the gas tap set to the minimum position.
If some ports do not light, increase the
minimum gas rate setting.
Check whether the burner remains lit
even when the gas tap is turned quickly
from the maximum to the minimum
position. If the burner does not remain
lit, increase the minimum gas rate
setting.
To adjust the minimum gas rate setting:
Semi-rapid and triple ring wok
burners
Light the burner.
Set the gas valve to
position.
Remove the knob.
Using a thin screwdriver, pass by the
hole of microswitch and turn the screw
“F” until adjustment is correct (Fig. 9a).
Inside crown of DUAL burner
Light the DUAL burner.
Set the gas valve to
position.
Remove the knob.
Using a screwdriver, turn the screw “H”
until the correct setting is obtained (Fig.
9b).
Outside crowns of DUAL burner
Light the DUAL burner.
Set the gas valve to
position.
Remove the knob.
Using a screwdriver, turn the screw “G”
until the correct setting is obtained (Fig.
9b).
For G30/G31 gas, tighten the adjustment
screws completely.