Fisher & Paykel OR120 Cooktop User Manual


 
6
Installation instructions
600 mm
1200 mm
MAX 927 mm
MIN 915 mm
120 mm
Fig. 1
Location
The installation conditions, concerning protection against overheating of the surfaces adjacent
to the cooker, must conform to Fig.3a or 3b.
The appliance must be kept no less than 200 mm away from any side wall which exceeds the
height of the hob surface (Fig. 3a or 3b).
The appliance must be housed in heat resistant units.
The walls of the units must be capable of resisting temperatures of 75 °C above room temperature.
Do not install the appliance near flammable materials (eg. curtains).
If the cooker is located on a pedestal, provide safety measures to prevent it falling out.
Assembling the backguard
It is mandatory to install the backguard
Assemble the backguard as shown in Fig. 2
and fix it by screwing the five screws “A”.
A
Fig. 2