PROXIMITY TO SIDE CABINETS
1. This range may be installed directly adjacent to existing 36” (914 mm)
high base cabinets.
Range dimensions:
width: 29” 7/8 (759 mm)
depth: 24” 3/16 (615 mm)
height (without backguard): MIN 35” 21/32 (906 mm) - MAX 36” 11/32
(923 mm)
backguard (height): 3” (76 mm)
Gas line opening: Wall - 37/64” (14.5 mm) from the right side to centre
of range; from 5” 7/16 (138 mm) to 6” 1/8 (155.5 mm) [depending on feet
regulation] from the oor.
Grounded outlet: should be located 37/64” (14.5 mm) from the left side
to centre of range; from 5” 7/16 (138 mm) to 6” 1/8 (155.5 mm) [depen-
ding on feet regulation] from the oor.
The electric cord with 4-prong ground plug (NEMA 14-50P) shall have
a minimum length of 48” (1220 mm) beyond the back of the appliance.
2. The range CANNOT be installed directly adjacent to sidewalls, tall cabi-
nets, tall appliances, or other side vertical surfaces above 36” (914 mm)
high.
There must be a minimum of 11” 13/16 (300 mm) side clearance from the
range to such combustible surfaces TO THE LEFT or TO THE RIGHT
above the 36” (914 mm) high countertop.
IMPORTANT: One side (left or right) above the 36” (914 mm) high
countertop must always be kept clear.
Island installation: There must be a minimum of 12” (305 mm) clearan-
ce from the rear of the backguard to such combustible surface on the
back of the range above the 36” (914 mm) high countertop.
3. The maximum upper cabinet depth recommended is 13” (330 mm). Wall
cabinet above the range must be a minimum of 30” (762 mm) above the
countertop for a width of minimum 30” (762 mm): it has to be centered
with the range. Side wall cabinets above the range must be a minimum
of 18” (457 mm) above the countertop.
installation
1
Fig. 1.1
3”
(76 mm)
MIN 35” 21/32 (906 mm)
MAX 36” 11/32 (923 mm)
24” 3/16
(615 mm)
29” 7/8
(759 mm)