Fisher & Paykel OR90 Cooktop User Manual


 
20
Installation instructions
Converting to a different gas type
This appliance is suitable for use with Natural gas or LPG (check the “gas type” sticker attached
to the appliance). To convert from one gas type to another, you need to replace the injectors,
and then adjust the minimum burning setting.
Replacing the injectors
1
Remove the trivets and burners from the cooktop.
2
Using a spanner, remove the injector (shown in Figs. 25-26 following) and replace it with one
according to the gas type (see the ‘Table for the choice of injectors’).
3
Fix the warning label (supplied with the conversion kit) at the back of the cooker, near the gas
inlet connections. This label states that the gas cooktop has been converted for use with LPG/
Natural gas.
Adjusting the minimum burner setting
4
Follow the instructions on Page 21, ‘Adjusting the minimum burner setting’.
Important!
If you are converting the cooker from Natural gas to LPG,remove the gas pressure regulator
before connecting the cooker to the gas supply and replace with the test point adaptor supplied
with the conversion kit.
If you are converting the cooker from LPG to Natural gas, remove the test point adaptor before
connecting the cooker to the gas supply and replace with the gas pressure regulator supplied
with the conversion kit.
Notes:
- The burners are designed so that regulation of primary air is not required.
Fig. 25 Auxiliary, rapid and semi-rapid burners Fig. 26 Triple-ring wok burner
Injector
OR90 MODELS
Injector