12
Attach the Syringe (continued)
Manually twist the barrel in a clockwise
direction until the luer lock connector is
finger tight and the ears of the barrel are
flush against the retaining plate. It may be
necessary to set the EXTEND/RETRACT
switch to RETRACT and step on the foot
pedal to bring the barrel ears completely
flush to the retaining plate. If you set the
switch to RETRACT be sure to set it back
to EXTEND before proceeding.
Note: Do not over-tighten the barrel. It is
only necessary to make a loose connection
to bring the barrel flush. The Retaining
Ring holds the barrel in place. Over
tightening can damage the piston hub.
Also, do not over retract the barrel ears.
Over retraction will cause air pockets
between the piston and material.
Slide the retaining ring cover over the
syringe and rotate the cover in a clockwise
direction.
The syringe should be firmly connected to
the dispensing gun.
7
6
5
Attaching the Syringe (continued)