Franke Consumer Products FCR 708-H TC Ventilation Hood User Manual


 
EN
1
1
11
Charcoal filter (recycling version)
This filter cannot be washed or regenerated. It must be replaced when the C appears on the
display or at least once every 4 months. The filter saturation alarm has to be activated already
before.
Activation of the alarm signal
In the recycling version hoods the filter saturation alarm must be activated during the instal-
lation or later.
Switch off the hood and the lights.
• Press the E-key for about 5 seconds until the last two segments of the motor LEDS are lit on
the display.
By releasing the E-key the clock icon starts to flash.
• Within 3 seconds press the D-key to activate/deactivate charcoal filter saturation alarm.
C-symbol lit - charcoal filter saturation alarm ACTIVATED.
C-symbol unlit - charcoal filter saturation alarm DEACTIVATED.
CHANGING THE ACTIVATED CHARCOAL FILTER
Resetting the alarm signal
• Press button G and hold it for at least 2 seconds.
Changing the Filter
If closed, open the Carriage by pressing button A and holding
for at least 1.5 seconds (see USE).
Open the comfort panel.
Remove the grease filters.
• Remove the saturated Activated Charcoal Filters, as indicated
(A).
Fit the new Filters, as indicated (B).
Replace the metal grease filters.
Close the comfort panel.
A
B
Lighting
LIGHT REPLACEMENT
20 W halogen light.
Extract the lamp from the lamp holder by pulling gently.
Replace with another of the same type, making sure that the two