Franke Consumer Products FDB 9078 SIL-K Ventilation Hood User Manual


 
EN
1
12
Charcoal filter (recycling version)
This filter cannot be washed or regenerated. It must be replaced when the EF appears on the
display or at least once every 4 months.
Activation of the alarm signal
In the recycling version hoods the filter saturation alarm must be activated during the instal-
lation or later.
Switch off the hood and the lights.
Disconnect the hood from the mains supply.
When restoring the connection press and hold B-key.
When releasing the key two rotating rectangles appear on the display.
Within 3 seconds press the B-key until a flashing confirmation appears on the dispaly:
2 flashes with EF - charcoal filter saturation alarm ACTIVATED
1 flash with EF - charcoal filter saturation alarm DEACTIVATED.
REPLACING THE CHARCOAL FILTER
Reset of the alarm signal
• Switch off the hood and the lighting. If the 24h-function has
been activated this has to be deactivated.
Press the E-key until the display is unlit.
Replacing of the filter
Open the comfort panels by pulling them downwards.
Remove the metal grease filters.
• Remove the saturated charcoal filter by releasing the fixing
hooks.
Fit the new filter and fasten it in its correct position.
Put the metal grease filters in their seats.
Close the comfort panels.
CHANGING THE SOUNDPROOFING ELEMENT
Open the Comfort panels by pulling them.
Remove the Metal grease filters.
• Remove the Activated charcoal filter, using the hooks pro-
vided.
• Pull out the Soundproofing Element from below, pressing the
side fins to disconnect it from the slot in the Hood Canopy.
Clean it with a damp cloth and replace it, first making sure that
it is completely dry.
Replace the Activated charcoal filters.
Replace the Metal grease filters.
Close the Comfort panels.