Franke Consumer Products FDB 9078 SIL-K Ventilation Hood User Manual


 
EN
7
7
Hood body installation
• Before hooking the hood body it is necessary to tighten 2 Vr screws
placed in the fixing points of the body.
Hook the hood body on the 12a screws.
• Tighten completely 12a support screws.
The correct hood body position can be levelled with Vr screws.
Fix the hood definitively by tightening the 12a security screws.
12a
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the hood body outlet.
Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
Remove any activated charcoal filters.
9
ø 120ø 150
AIR OUTLET - RECIRCULATION VERSION
Connect the Flange ø150 10 to the bottom end of the Connec-
tor 15
Join the Hood canopy outlet to the Flange on the bottom part of
the Connector, using a rigid or flexible pipe ø150 mm, selec-
tion of which is at the discretion of the installation technician.
• Make sure that the Activated charcoal odour filter has been
fitted.
ø 150
15
10