Franklin Industries, L.L.C. FIM400 4100 Ice Maker User Manual


 
9
(38ºC). This unit MUST be installed in an area protected from the elements, such as
wind, rain, water spray or drips.
? The unit should not be located next to ovens, grills or other sources of high heat.
? Installation of the ice maker requires a cold water supply inlet of 1/4? (6,35 mm) soft
copper tubing with a shut-off valve.
? The ice maker requires a continuous water supply with a minimum pressure of 15 psig
and a static pressure not to exceed 80 psig. The temperature of the water feeding into
the ice maker should be between 41ºF (5ºC) and 90ºF (32ºC) for proper operation.
? In general, it is always a good idea to filter the water. A water filter, if it is of the proper
type, can remove taste and odors as well as particles.
? The ice maker must be installed with all electrical and water connections in accordance
with state and local codes.
? The ice maker and bin should be located on a firm and level surface. It is important for
the ice maker to be perfectly level for proper operation; otherwise water may not flow
properly through the evaporator (ice mold). Ice production will be less than expected
and operation will be noisy.
? The feet of most bins can be rotated to adjust the height if necessary. Follow
instructions accompanying the bin you purchase.
Electrical Requirements
Before you move your ice maker into its final location, be sure you have the proper
electrical connection. A standard electrical supply (115 VAC only, 60 Hz, 20A),
properly grounded in accordance with National Electrical Code and local codes and