ALERTS
ALERTS
There are four possible conditions that will cause the alert tone to sound.
High Temp Alert
If the temperature inside the cabinet has exceeded 23ºF (-5ºC) for 1 hour or more of normal operation, the HIGH
TEMP LED will illuminate, the HIGH TEMP Alert will sound and the cabinet temperature is shown in the display. The LED
and temperature alert will remain active until the cabinet temperature is below 23ºF (-5ºC).
The audible alert can be turned off by pressing Alert Reset key.
Door Ajar Alert
This alert will sound to alert you that the door has been open for 5 minutes or more. The DOOR AJAR LED will
illuminate and the audible alert will sound until the door is closed.
The audible alert can be turned off by pressing the Alert Reset key or by closing the door. If the door is ajar for 15
minutes, the interior light will turn off.
Temp Sensing Error Alert
The sensor alarm signals you that a problem exists with a temperature sensor. The audible alarm will sound after one
(1) hour and the display will alternate between “E8” or “E9” and -10°F (-23°C) at ½ second intervals. The control will
then enter a mode that runs the freezer in a manner that maintains the factory set cabinet temperature.
The audible alert can be turned off by pressing the Alert Reset key.
Stuck Key Alert
The stuck key alert will sound if the control reads a keypress for longer than 30 seconds. The audible alert will sound
and will be limited to one minute and will stop automatically. The display will alternate between “E7” and -10°F
(-23°C) at ½ second intervals and the control will run the freezer continuously until the condition is resolved.
The audible alert can be turned off by pressing the Alert Reset key.
°F
HI-TEMP