Frymaster 17ECS Cooktop User Manual


 
3-9
The computer can be programmed for either “standard” or “slow” clock times. The standard clock
displays minutes and seconds, the slow clock displays hours and minutes.
To toggle back and forth between times press the Program Mode switch, then enter the code
1 6 5 3 using the product buttons.
SELECTING BOIL OR SIMMER MODE
In the SIMMER mode, the water temperature is maintained at the setpoint programmed by the
operator. In the BOIL mode, the water temperature is raised to 212°F (100°C).
Select the SIMMER mode by pressing the R button. If the temperature of the water is above the
setpoint, °-hi will be displayed. If the temperature of the water is below the setpoint, °-lo will be
displayed. If the temperature is within 11°F (6°C) of the setpoint, “- - - -” will be displayed.
The BOIL mode is selected by pressing the L button. The display will show
boil
and the
temperature of the water will be raised to 212°F (100°C).
3.2.3 Shutting the EWBS with CM III Computer Down
Turn the unit off by pressing the Power switch.
If shutting down at the end of the day, drain and clean the cookpot, and put the cookpot cover in
place.
CAUTION
The electronic circuitry in your computer can be affected adversely by power fluctuations
and electrical storms. If it fails to function or program properly for no apparent reason, try
unplugging the computer from the interface board and plugging it back in. This could
prevent a service call.
3.3 Thermostat Control and Switch Panel (Used on ESW and EWBS Units)
2
2
5
2
1
5
2
0
5
1
9
5
1
8
5
1
7
5
165
1
5
5
SWITCH PANEL
THERMOSTAT CONTROL
POWER
TROUBLE
POWER
BOIL
IDLE
SIMMER
ON
OFF
ON
OFF
ON
OFF
HEAT CYCLE
FAUCET SKIM
CAUTION
If this is the first time the unit is being used after installation, refer to Section 3.4, Boil Out
Procedure.