Frymaster 2424G Fryer User Manual


 
7-1
LJS 24G SERIES FLATBOTTOM GAS FRYERS
CHAPTER 7: TROUBLESHOOTING
FACTORY APPROVAL MUST BE OBTAINED PRIOR TO ANY WARRANTY WORK BEING
DONE OR DEAN CANNOT BE HELD RESPONSIBLE.
The following procedures must be performed by Factory Authorized Service Technicians, and are
provided as an aid to expedite troubleshooting and repair of LJS 24G Series frying systems.
7.1 PILOT BURNER MALFUNCTIONS
PROBLEM CORRECTIVE ACTION
Pilot will not ignite; no
evidence of gas at pilot
burner.
Ensure the combination gas valve is in PILOT position and that
gas is available at the control valve (check quick-disconnect
and/or gas-line connections for proper connection).
Pilot burner ignites but will
not remain lit when gas
knob is released.
Pilot flame may be adjusted incorrectly. Adjust flame to 1½"
high by turning pilot flow adjustment screw.
Pilot burner ignites
properly and burns
properly, but goes out
when the exhaust blower
comes on.
1. Pilot flame may be adjusted too low, even though it
appears to be satisfactory. Re-adjust higher as described
earlier.
2. Pilot flame may be adjusted too high and is on the verge
of blowing out. Re-adjust lower.