Frymaster 52 Series Fryer User Manual


 
3-10
3.7 Gas Conversion: Procedures (cont.)
When converting from G20 (20 mbar) to G25 (25 mbar), or vice-versa, or G31 (37 mbar) to G31 (50
mbar), the following procedures apply:
Check pilot-adjustment and adjust as necessary.
Other adjustments are not necessary.
Conversion from one gas family to another (i.e. changing from natural gas to propane) requires
special components. Obtain the necessary components using the cross-reference in Section 3.8, Gas
Conversion Components.
Conversions can only be executed by qualified, factory-authorized personnel.
ON Button- Pilot Gas-flow OFF Button
Pressure flow adjustment
Thermocouple connection Pilot flow adjustment
Vent tube connection
Pressure flow adjustment
(remove cover screw to access)
ON/PILOT/OFF
Gas-Cock Knob
Pilot gas supply connection
Regulator Vent
Pilot pressure adjustment
(remove cover screw to access)
Pressure Tap
CE Gas Valve