3-12
3.8 Gas Conversion Kits (cont.)
SR52G Propane to Natural Gas Components
QTY REF DESCRIPTION
1 TJ024 Pilot orifice
5 14-0067-1
Burner orifice, #39
(diameter: 2.53 mm)
1 Label
Appareil réglé pour: G20/20
Fryer equipped for: G25/25
3.9 Electrical Connections
No outside electrical power source is required for Super Runner gas fryers unless outfitted with
certain optional equipment (i.e. basket lifts). Refer to the rating plate and wiring diagram located
inside the front door. The diagram can also be found in Section 8.4. All electrically operated
appliances must be electrically grounded in accordance with local codes, or in the absence of local
codes, with the National Electrical Code (ANSI/NFPA 70), the Canadian Electrical Code (CSA
C22.2), or the appropriate CE community standards. Do not cut or remove the ground prong from
the power cord plug. Respect the phase – neutral polarity.