Frymaster 819-5432 Fryer User Manual


 
3 of 9
© 2000 McDonald’s Corporation 819-5432 NOV 05
All Rights Reserved Card 15
Recovery Check Time (With Thermostat Controller only.)
9. If the required recovery time cannot be attained, call service representative.
Caution: Turn thermostat knob back to normal cooking temperature before putting fryer
back in service.
Recovery Check Time (With MACC100A, M100A, and M100B Computer
only.)
Note: With the MACC100A, M-100A, and M100B cooking computers, Recovery Time
Checks are performed automatically and updated each time the vat temperature rises
from 250°F (121°C) to above 320°F (160°C).
1. Turn the fry vat ON by pressing the
button (MACC100A and M100A), or the button
(M100B). The previously cooked product should be displayed on the computer.
2. To display the most recent recovery test time, press the
button in the following manner:
3. Record the recovery time.
Note: Recovery time should be less than 145 seconds for a gas fryer (less than 155
seconds for M100B computers only), and less than 100 seconds for an electric fryer. If
time is less than 145 seconds for gas (155 seconds—M100B only), or 100 for electric
fryers, recovery time is acceptable. If the time displayed is greater than the required
time, refer to the scratch calibration procedure on this card or the Fryer section of the
Equipment Manual for Troubleshooting Charts and check the following:
a. Grease filter condition
b. Cooking oil level
c. (Gas fryers) Proper placement of seal angle, gravity blade and standoff
d. (Gas fryers) Air flow, combustion air blower
e. (Gas fryers) Radiant burner condition
f. (Electric fryers) Large power plug plugged in properly.
4. Repeat steps 1 through 3 for each additional vat.
5. Recovery time check is complete.
Recovery Check Time (With M2000 Computer only.)
Note: With the M2000 cooking computer, Recovery Time Checks are performed
automatically and updated each time the vat temperature rises from 250°F (121°C) to
above 320°F (160°C).
1. Turn the fry vat OFF by pressing the
button. The computer should display OFF. The
computer must be off to enter the programming mode.
2. Enter the programming mode by pressing the
button. Code will show in the left
display.
3. Enter the code
1 6 5 2
(1652). The most current recovery time will appear in both
displays.
Continued from previous
page.
When
Monthly
Tools
Paper, pen.
When
Monthly
Tools
Paper, pen.
Full-vat:
Left
or right
button.
Split-vat, left:
Left
button.
Split-vat, right:
Right
button.