Frymaster E4 Fryer User Manual


 
4-6
4. After the oil has drained from the frypot,
turn the filter handle to the ON position
to start the pump and begin the filtering
process. There may be a slight delay
before the pump activates.
5. The filter pump draws the oil through the filter medium and circulates it back up to and through
the frypot during a 5-minute process called polishing. Polishing cleans the oil by trapping solid
particles in the filter medium.
6. After the oil is filtered (about 5 minutes), close the drain valve and allow the fryer to refill. Let
the filter pump run 10 to 12 seconds after the oil begins to bubble. Turn the filter off.
WARNING
The filter pump is equipped with a manual reset switch in case the filter motor
overheats or an electrical fault occurs. If this switch trips, turn off power to the filter
system and allow the pump motor to cool 20 minutes before attempting to reset the
switch (see photo below).
Filter Pump Reset Switch
7. Lower the elements into the frypot and reinstall the basket support rack.
Turn filter handle to
the ON position