Frymaster E4 Fryer User Manual


 
ii
DANGER
Adequate means must be provided to limit the movement of this appliance without depending
on or transmitting stress to the electrical conduit. A restraint kit is provided with the fryer. If
the restraint kit is missing contact your local Frymaster Factory Authorized Service Center
(FASC) for part number 826-0900.
DANGER
Prior to movement, testing, maintenance and any repair on your Frymaster fryer, disconnect all
electrical power from the fryer.
ELECTRICAL POWER SPECIFICATIONS
Three (3) Phase Requirements
MINIMUM SIZE AMPS PER LEG
kW VOLTAGE PHASE
WIRE
SERVICE
AWG mm
2
L1 L2 L3
14 208 3 3 6 16 39 39 39
14 240 3 3 6 16 34 34 34
14 480 3 3 8 10 17 17 17
14 220/380 3 4 6 16 21 21 21
14 240/415 3 4 6 16 20 20 21
14 230/400 3 4 6 16 21 21 21
208 3 3 6 16 39 39 39
240 3 3 6 16 34 34 34
220/380 3 4 6 16 21 21 21
ALL
EPRI 14kW
(SOLID STATE)
240/415 3 4 6 16 20 20 20
17 208 3 3 6 16 48 48 48
17 240 3 3 6 16 41 41 41
17 480 3 3 6 16 21 21 21
17 220/380 3 4 6 16 26 26 26
17 240/415 3 4 6 16 24 24 24
17 230/400 3 4 6 16 25 25 25
208 3 3 6 16 48 48 48
240 3 3 6 16 41 41 41
220/380 3 4 6 16 26 26 26
ALL
EPRI 17kW
(SOLID STATE)
240/415 3 4 6 16 24 24 24
22 208 3 3 4 25 61 61 61
22 240 3 3 4 25 53 53 53
22 480 3 3 6 16 27 27 27
22 220/380 3 4 6 16 34 34 34
22 240/415 3 4 6 16 31 31 31
22 230/400 3 4 6 16 32 32 32
Single Phase Requirements
MINIMUM SIZE
kW VOLTAGE PHASE
WIRE
SERVICE
AWG mm
2
AMPS
14 208 1 2 3 34 68
14 240 1 2 4 25 59
14 480 1 2 8 10 30