Frymaster FPD Fryer User Manual


 
DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-29
1.7.8 Replacing the Frypot (cont.)
27. Remove the temperature probe from frypot. (See Section 1.7.3, Replacing the Temperature
Probe: Computer –equipped Fryers, for specific instructions.)
28. Remove the high-limit and backup thermostats. Follow Steps 5-7, Section 1.7.4, Replacing
the High-limit Thermostat, and Section 1.7.2, Replacing Backup Thermostat, (where
applicable) from frypot.
29. If the fryer is equipped with
drain-valve microswitches,
mark the wires and
microswitch terminals, then
disconnect wires from the
switch. Secure the wires to
prevent damage when frypot
is removed.
30. Remove bolts from brackets securing burner manifold to frypot. Leave the manifold in
place.
Left: Microswitch wires marked for removal (ensure microswitch
terminals are marked the same as the wires removed). Right:
Microswitch mounted to drain valve.
Removing bolts (arrows) from burner manifold
support brackets (both sides). Leave the burner
manifold in place after removing bolts.