Frymaster FPD Fryer User Manual


 
DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-1
1.1 Functional Description
Decathlon Series gas fryers contain a welded steel frypot (stainless or cold-rolled) heated by gas
flames diffused evenly through tubes built into the frypot.
Flames originate from orifices in a burner manifold positioned beneath cast-iron burners. The
burners are positioned in the tube openings, at the front of the frypot. The diameter of the orifices
differs for natural (CE:G20/G25) and LP (CE:G31) gas as indicated in the accompanying table.
NON-CE
(
Altitudes of 2000 feet or less
)
EQUIPMENT
PRESSURE
MODEL
INPUT
(BTU)
GAS
TYPE
ORIFICE
MM
(INCH)
ORIFICE
PART NO.
QTY
MBAR INCH W.C.
D20G 50
NAT
LP
2.18(#44)
1.40(#54)
810-2050
810-2324
2
2
10
27.5
4
11
D50G 85
NAT
LP
2.08(#45)
1.32(#55)
14-0067-45
810-2441
4
4
10
27.5
4
11
D50G(HP) 120
NAT
LP
2.53(#39)
1.51(#53)
810-2048
810-2059
4
4
10
27.5
4
11
D50GDDHP 115
NAT
LP
2.44(#41)
1.51(#53)
14-0067-41
810-2059
4
4
10
27.5
4
11
D60G 112
NAT
LP
2.08(#45)
1.32(#55)
14-0067-45
810-2441
5
5
10
27.5
4
11
D60G(HP) 150
NAT
LP
2.53(#39)
1.51(#53)
810-2048
810-2059
5
5
10
27.5
4
11
D80G 122
NAT
LP
2.26(#43)
1.40(#54)
810-2049
810-2324
5
5
10
27.5
4
11
D80G(HP) 165
NAT
LP
2.58(#38)
1.61(#52)
810-2062
810-2063
5
5
10
27.5
4
11
CE ONLY
(
Altitudes of 2000 feet or less
)
EQUIPMENT
PRESSURE
MODEL
INPUT
(kW)
GAS
TYPE
ORIFICE
MM
(INCH)
ORIFICE
PART NO.
QTY/
COLOR
MBAR INCH W.C.
D20G 15,0
G20
G25
G31
2,40
2,40
1,51
810-2060
810-2060
810-2059
2/BLUE
2/BLUE
2/RED
10,0
15,0
27,0
4,0
6,0
10,8
D50G 30,0
G20
G25
G31
2,40
2,40
1,51
810-2060
810-2060
810-2059
4/BLUE
4/BLUE
4/RED
10,0
15,0
27,0
4,0
6,0
10,8
D60G 37,5
G20
G25
G31
2,40
2,40
1,51
810-2060
810-2060
810-2059
5/BLUE
5/BLUE
5/RED
10,0
15,0
27,0
4,0
6,0
10,8
D80G 37,5
G20
G25
G31
2,40
2,40
1,51
810-2060
810-2060
810-2059
5/BLUE
5/BLUE
5/RED
10,0
15,0
27,0
4,0
6,0
10,8