Frymaster GF14 Fryer User Manual


 
2-4
1. Connect the quick-disconnect hose to the fryer quick-disconnect fitting at the rear of the fryer
and to the building gas line.
NOTE: Some fryers are configured for a rigid connection to the gas supply line. These units
are connected directly to the gas supply line.
When using thread compound, use very small amounts on male threads only. Use a pipe thread
compound that is not affected by the chemical action of LP gases (Loctite™ PST56765 Sealant
is one such compound). DO NOT apply compound to the first two threads. This will ensure that
the burner orifices and control valve do not become clogged.
2. Open the gas supply to the fryer and check all piping, fittings, and gas connections for leaks. A
soap and water solution should be used for this purpose.
DANGER
Never use matches, candles, or any other ignition source to check for leaks.
If gas odors are detected, shut off the gas supply to the fryer at the main shut-off
valve and contact the local gas company or an authorized service agency for service.
NOTE: The fryer must be disconnected from the gas supply piping during any pressure testing
of the gas supply piping a pressures equal to or greater than ½ psig (3.45kPa or 13.84 in. W.C.).
3. Close the fryer drain valve and fill the frypot with water or boil-out solution to the bottom OIL-
LEVEL line at the rear of the frypot. Light the fryer and perform the boil-out procedures that are
described in the “Start-Up Procedure” and “Boiling Out the Frypot” topics found in Chapter 3 of
this manual.
WARNING
“Dry-firing” your unit will cause damage to the frypot. Always ensure that melted
shortening, cooking oil, or water is in the frypot before firing your unit.
4. It is suggested that the burner manifold pressure be checked at this time by the local gas
company or an authorized service agent. Refer to “Check Burner Manifold Pressure” in Section
4.3 of this manual for the proper procedure.
5. Check the thermostat calibration in accordance with the instructions in Section 4.3 of this
manual.
2.5 Converting to Another Gas Type
DANGER
Switching to a different type of gas without installing the proper conversion kit may
result in fire or explosion.
NEVER ATTACH YOUR FRYER TO A GAS SUPPLY FOR WHICH IT IS NOT
CONFIGURED!