Problem Probable Causes Corrective Action
Basket lift timer
display shows
.
Problem with the temperature
measuring circuitry including the
probe.
This indicates a problem within the
temperature measuring circuitry
that is beyond the scope of
operator troubleshooting. Shut the
fryer down and call FASC.
CM III display is in
wrong temperature
scale (Fahrenheit or
Celsius).
Incorrect display option programmed.
CM III computers may be
programmed to display in either
Fahrenheit or Celsius. Refer to the
separate Frymaster Fryer
Controllers User's Manual for
instructions on changing the
display.
CM III
or
Digital Controller
display shows
.
Open drain valve or problem with
latching circuitry.
Verify that the drain valve is fully
closed. The fryer will not function
if the drain valve is not fully
closed. If the drain valve is fully
closed, the problem is within the
latching circuitry and is beyond the
scope of operator trouble shooting.
Call FASC.
display shows
.
Fryer is more than 21ºF (12ºC) above
setpoint.
This display is normal if the fryer
setpoint has been changed to a
lower temperature. The display
should revert to the normal four
dashes when the frypot
temperature cools to the setpoint.
If the setpoint has not been
changed, this indicates a problem
with the temperature control
circuitry. Turn the fryer off and
call FASC.
CM III
or
Digital Controller
display shows
.
Frypot temperature is more than
410ºF (210ºC) or, in CE countries,
395ºF (202ºC).
This in an indication of a
malfunction in the temperature
control circuitry, including a
failure of the high-limit thermostat.
Shut the fryer down immediately
and call FASC.