6-3
Filter Pump Fails To Pump Oil
If filter unit has a
heater, turn heater
ON and allow to
heat for 20
minutes.
Insert flexible oil
return hose into
filter pan and turn
pump motor ON.
Does oil flow through oil
return hose?
Proceed with normal
operations.
Disconnect flexible oil return
hose. Make sure it is cool before
handling. Try blowing air through
the hose.
Can you blow
air through it?
Submerge hose in very hot water,
keeping the water out of the hose.
Water in the hose will cause severe
splattering when hot oil is circulated
through the hose.
Once shortening has had time
to soften, reconnect hose to
filter pump.
Filter
pump
fails to
pump
oil.
Yes
No
Yes
Blockage is between bottom of the filter
pan and the flexible hose quick
disconnect. Go to "Blockage Between
Filter Pan and Flex Hose Valve.
No