Frymaster MJCFE Fryer User Manual


 
MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-11
1.8.3 Replacing Temperature Probe
1. Disconnect the fryer from the electrical supply.
2. Drain the frypot.
3. Remove the screws from the upper left and right corners of the control panel. The panel is
hinged at the bottom and will swing open from the top.
4. Unplug the wiring harness from the back of the controller and disconnect the grounding wire
(see Section 1.8.1, Step 4).
5. Remove the controller from the fryer by lifting it from the hinge slots in the control panel frame.
5. Remove the two screws from the base of the interface board mounting-bracket.
6. Disconnect the 12-pin plug from the back of the interface board and lay the board in the left end
of the compartment with all other wires still connected.
7. Remove the 12-volt transformer from the component shield and lay it in the left end of the
compartment with wires still connected.
8. Using a pin-pusher, remove the temperature probe wires (pins 1 and 2) from the 12-pin plug
disconnected in step 7.
9. Unscrew the temperature probe from the frypot and remove.
10. Apply Loctite PST567 thread sealant or equivalent to new probe threads.
11. Reverse steps 1 through 10 to install the replacement probe.
1.8.4 Replacing High-Limit Thermostat – Operating Thermostat Controls
1. Disconnect the fryer from the electrical supply.
2. Drain the frypot.
3. Loosen the setscrew securing the thermostat knob and remove the knob. Remove the screws
from the upper left and right corners of the control panel. The control panel is hinged at the
bottom and will swing open from the top.
4. Disconnect the 9-pin connector and remove the control panel from the fryer by disengaging its
tabs from the hinge slots in the mounting frame.
5. Disconnect the high-limit thermostat leads from the gas valve pilot coil.