Garland ECG Griddle User Manual


 
2
DO NOT operate the product unless all service and access panels are in place and fastened
properly.
DO NOT attempt to repair or replace any part of this product unless all main power supplies
have been disconnected.
WARNING - to avoid personal injury:
USE EXTREME CAUTION in setting up, operating and cleaning this product to avoid coming
into contact with hot grill surfaces or hot grease. Suitable protective clothing should be worn to
prevent the risk of burns.
NOTE all warning labels and markings on the product, which call attention to further dangers
and necessary precautions.
WARNING – This appliance must not be cleaned with a water jet.
TECHNICAL SPECIFICATIONS
LOADING CHART
LOAD PER PHASE AMPS PER PHASE
MODEL
TOTAL
kW LOAD
Voltage
X-Y X-Z Y-Z X Y Z
Amps
1 phase
8.60 208 2.60 3.00 3.00 23.3 23.3 25.0 41.3
ECG-24R
8.60 240 2.60 3.00 3.00 20.2 20.2 21.7 35.8
12.90 208 4.30 4.30 4.30 35.8 35.8 35.8 62.0
ECG-36R
12.90 240 4.30 4.30 4.30 31.0 31.0 31.0 53.8
17.20 208 5.60 6.00 5.60 48.3 46.6 48.3 82.7
ECG-48R
17.20 240 5.60 6.00 5.60 41.9 40.4 41.9 71.7
21.50 208 6.90 7.30 7.30 59.1 59.1 60.8 103.4
ECG-60R
21.50 240 6.90 7.30 7.30 51.2 51.2 52.7 89.6
25.80 208 8.60 8.60 8.60 71.6 71.6 71.6 124.0
ECG-72R
25.80 240 8.60 8.60 8.60 62.1 62.1 62.1 107.5
EXTERIOR DIMENSIONS
MODEL HEIGHT WIDTH DEPTH WEIGHT
mm ins mm ins mm ins kg Lb.
ECG-24R 905 35 5/8 610 24 889 35 120 265
ECG-36R 905 35 5/8 914 36 889 35 181 400
ECG-48R 905 35 5/8 1219 48 889 35 227 500
ECG-60R 905 35 5/8 1524 60 889 35 272 600
ECG-72R 905 35 5/8 1829 72 889 35 318 700
ELECTRICAL SUPPLY
Before attempting the electrical connection, the rating plate should be checked to ensure that the
equipment’s electrical characteristics agree. On Electric Chain Griddles, the supply entrance is
located at the rear of the main bottom. The supply terminal block is accessible from the front.
ELECTRICAL SUPPLY
CONTINUED
The electrical supply must be adequate for the voltage, phase and current marked on the rating
plate.