INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATIONS
SITE REQUIREMENTS
• These appliances have 3 modes of operation:
a) flame effect only - with brightness and flame speed
adjustment
b) flame effect + 1kw heating
c) flame effect + 2kw heating
ALL 'INGLENOOK' FIREPLACE OPENINGS:
FOR ALL MODELS, THE DIMENSIONS REQUIRED FOR AN
'INGLENOOK' TYPE OF INSTALLATION CAN BE CALCULATED
BY ADDING 225 mm (9") TO THE HEIGHT AND 150 mm (6")
TO EACH SIDE, ADDING 300 mm (12") TO THE APPLIANCE
WIDTH. AN ADDITIONAL 50mm (2") MUST BE ADDED TO
THE DEPTH DIMENSION TO PROVIDE ADEQUATE SPACE
BEHIND THE APPLIANCE.
KEY TO SUFFIXES
Anthracite = AN Midnight Blue = B
Stainless Steel = BS Ivory = V
Matt Black = None Laurel = LG
• A 230v 13amp 50Hz supply is required.
• Maximum power consumption: 2064 watts.
• THISAPPLIANCEMUSTBEEARTHED
• A 1.8 metre plug and lead are supplied
• Bulbtypes:2X40watt‘Elegance’SoftE.S.(E14)candle
lamp (fused)
• Remotecontrolhandsetbattery(CR2025)
Manhattan Small E8622 / AN / BS Clarendon Medium Clear E8612 / B / LG
Manhattan Medium E8619 / AN / BS Huntingdon E8503 / B / LG / V
Ashdon Medium E8613 / B / LG / V Marlborough Small E8560
Clarendon Small E8517 Marlborough Medium E8610
Clarendon Medium E8612 Stockton Small E8573
Clarendon Small Clear E8517 / B / LG Stockton 5 (Midi) E8575
Stockton Medium E8617
These instructions cover the following models:
SMALL MARLBOROUGH DIMENSIONS
1
410mm
533mm
280mm
80mm