6a.4 Replace the grate in the reverse order from removal.
6a.5 The grate must sit flat on the side supports, with no debris
trapped under it. Check that the centre grate sits flat and
rotates freely with no debris trapped under it.
6B. FIREGRATE REMOVAL (RIVA AVANTI)
(Tools required – None)
6b.1 To remove the firegrate first remove the centre grate:
•Disconnecttheoperatinglinkagefromthegrate
•MovethePrimaryaircontroltothefullyopenposition
•Springtheoperatinglinkforwardtodisconnectthe
balljoint
The centre grate can then be lifted out from inside of the
firebox.
11
6b.2 The main grate can then be lifted out of the firebox.
6b.3 Replace the grate system in the reverse order from removal.
6b.4 Ensure that the seal tape on the underside of the grate is in
good condition and correctly fitted. If not replace with new.
(Stovax part number 4998)
PR7061
Seal Tape
12
6b.5 The grate must sit flat on the side supports, with no debris
trapped under it. Check that the centre grate sits flat and
rotates freely with no debris trapped under it.