Stovax RVF40AVH Range User Manual


 
9
OPERATING INSTRUCTIONS
WARNING
Do not use the door as a rest or support when refuelling
or adjusting the air controls as this could cause
p
ermanent damage to the appliance.
5.1 Do not use the appliance at maximum output for prolonged
periods of time, or over fill the firebox with fuel, as this
could result in over-firing. If the connecting fluepipe,
appliance flue collar or top plate glow red with heat the
appliance is being over-fired and the air controls should be
closed to reduce the output.
5.2 If a chimney fire occurs shut all air controls immediately to
close the appliance down, and evacuate all persons from
the building before calling the fire brigade. Do not re-enter
the building until it is confirmed safe to do so.
5.3
Following a chimney fire do not use the appliance until it is
inspected, by a HETAS (GB only)/INFO (Eire) registered
installer, to confirm that the appliance is safe to use, or
make any repairs required before re-use. Only genuine
Stovax replacement parts are to be used to keep your
appliance in safe and efficient working order.
5.4
After any chimney fire it is recommended that the chimney
system be inspected and swept by a NACS registered (UK
only) chimney sweep, to confirm that the system is
structurally sound and free from any obstructions before re-
use.
6.1 If the stove is not to be used during the warmer periods of
the year it is recommended to clean and service the stove,
as detailed in the Maintenance and Servicing section.
6.2 The air controls should be set in the 50% open position to
k
eep the appliance ventilated, and stop the build-up of any
moisture inside.
6
.3 Before re-lighting the stove remove the baffles, clear any
debris that may have accumulated, and check the flue is
clear of any blockages.
7.1 The burning of any fuel will produce ash, which will have to
be removed after a period of use. This time will depend on
the fuel used. Before removing the ash from the stove it is
advisable to let the fire burn down to a low level, or even
go out completely. The ash pan can the be removed from
the appliance using the tool provided, after lowering the
access cover below the door. See section 1.12.
5. OVER-FIRING
6. SEASONAL USE
7. ASH REMOVAL
P
R7173
PR7174
PR7093
PR7097
RIVA AVANTI
RIVA CUBE
Riva Cube
R
iva Avanti