DUCTING CHART–JV5 Series Models
DUCTING CHART–JV6 Series Models
Equivalent Length in Feet
0 25 50 75 100 125 150
3
1
4x 10 Rectangular Transition to 6Round = 4.5 ft.
7
Round 90° Elbow = 8 ft.
7
Roof Cap = 30 ft.
250
200
150
100
Air Volume in CFM
3
1
4 x 10
Rectangular
7Round
Equivalent Length in Feet
0 25 50 75 100 125 150
3
1
4x 10Rectangular Transition to 6Round = 4.5 ft.
7
Round 90° Elbow = 8 ft.
7
Roof Cap = 30 ft.
400
350
300
250
200
Air Volume in CFM
3
1
4x 10
Rectangular
7Round
Follow the guidelines for proper duct sizing in the ducting charts.
Installation Instructions
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of a 3
1
4 x 10 rectangular,
6 or 7 diameter round duct should not exceed 65 equivalent feet.