GE JV535, JV536, JV565, JV566, JV635, JV636, JV665, JV666 Ventilation Hood User Manual


 
DUCT EQUIVALENT NUMBER
PIECES LENGTH x USED = TOTAL
3
1
4x 10 1 Ft. x ( ) = Ft.
Rect.,
straight
7Round, 1 Ft. x ( ) = Ft.
straight
6Round, 1 Ft. x ( ) = Ft.
straight
3
1
4x 10 8.5 Ft. x ( ) = Ft.
Rect. 90°
elbow
3
1
4x 10 7 Ft. x ( ) = Ft.
Rect. 45°
elbow
3
1
4x 10 24 Ft. x ( ) = Ft.
Rect. 90°
flat elbow
3
1
4x 10 45 Ft. x ( ) = Ft.
Rect.
(7 ft. w/o
wall cap
damper)
x ( ) = Ft.
with
damper
3
1
4x 10 4.5 Ft. x ( ) = Ft.
Rect. to
6round
transition
3
1
4x 10 11.5 Ft. x ( ) = Ft.
Rect. to
6round
transition
90° elbow
6Round, 8 Ft. x ( ) = Ft.
90° elbow
6Round, 6.5 Ft. x ( ) = Ft.
45° elbow
Subtotal column 1 = Ft.
8
WORKSHEET – CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH
DUCT EQUIVALENT NUMBER
PIECES LENGTH x USED = TOTAL
6Round 34 Ft. x ( ) = Ft.
wall cap
(6 ft. w/o
with
damper)
x ( ) = Ft.
damper
6Round 30 Ft. x ( ) = Ft.
roof cap
6Round 5.5 Ft. x ( ) = Ft.
to
3
1
4x 10
rect.
transition
6Round 14.5 Ft. x ( ) = Ft.
to
3
1
4x 10
rect.
transition
90° elbow
7Round, 8 Ft. x ( ) = Ft.
90° elbow
7Round, 6.5 Ft. x ( ) = Ft.
45° elbow
7Round 34 Ft. x ( ) = Ft.
wall cap (
6 ft. w/o
with
damper)
x ( ) = Ft.
damper
7Round 30 Ft. x ( ) = Ft.
roof cap
7Round 5.5 Ft. x ( ) = Ft.
to
3
1
4x 10
rect.
transition
7Round 14.5 Ft. x ( ) = Ft.
to
3
1
4x 10
rect.
transition,
90° elbow
Subtotal column 2 = Ft.
Subtotal column 1 = Ft.
Total ductwork =
Ft.
Installation Instructions
MAXIMUM DUCT LENGTH: For satisfactory air
movement, the total duct length of a 3
1
4 x 10
rectangular, 6or 7 diameter round duct should
not exceed 65 equivalent feet.