GE JVB37 Ventilation Hood User Manual


 
Consumer Support
Operating InstructionsSafety Instructions
Installation Instructions Troubleshooting Tips
Connect Power
Plug power cord into a properly grounded receptacle.
Optional Kits
JXRB57
optional accessory for indoor remote
location of the blower/motor assembly. Use this
kit when the blower and motor assembly will be
located outside or below the cabinet floor.
JXBC57
optional outdoor cover accessory for
remote installation of blower and motor assembly
on an outside wall.
Installing the Cooktop
With the Downdraft in the “Down” position,
place the cooktop into the cutout.
Push the cooktop back until the back edge of
the cooktop just barely touches the front edge
of the downdraft cover.
Using a dime as a thickness gauge, align the
cooktop so that there is a minimum uniform
gap of 0.05 (the thickness of a dime) between
the cooktop and the downdraft cover.
NOTE:
Do not force the downdraft cover to move
rearward when aligning the cooktop. This may
cause the downdraft cover to impact and damage
the cooktop when the vent is raised and lowered.
NOTES:
Accurate alignment of cooktop and downdraft
is necessary to ensure that there is no
interference when air vent is raised and
lowered. There should be a gap of 0.05
(the thickness of a dime) between the back
edge of the cooktop and the front edge of
the downdraft cover.
Radiant cooktops cannot be flush mounted
when using this downdraft vent.
17