GE r08654v-1 Oven User Manual


 
11
NOTE: This oven is only
approved to be installed under
the specific models as labeled
on this unit.
Side by Side Installations
Install two wall ovens in separate cutouts.
Allow 2 (5.1 cm) min. between cutouts.
Installation Instructions
Cutout for 30
(76.2 cm)
Single Built-In Ovens
only
Under Counter
For JTP30, JTP70, PT916, PT920, ZET938 models only.
MUST SUPPORT 150 LBS. (68 Kg)
Gas and electrical connections
for gas cooktop must be located
in an adjacent accessible
location to the right.
240V / 208V
Junction Box
Location (junction
box may be in
adjacent cabinet)
Allow 1 (2.5 cm)
overlap top
of oven,
11/16(1.8 cm)
overlap side edges
of cutout and
1 1/4 (3.2 cm)
overlap bottom
of oven.
Top and/or side fillers
may be necessary
if unit is positioned
between existing
cabinets. Be sure
they are attached
securely, since they
will anchor the oven
in the cabinet.
Gas or electric cooktops may be installed over this oven. See
cooktop installation instructions for cutout size. See label on
top of oven for approved cooktop models.
28 1/2(72.4 cm) Min.
28 5/8(72.7 cm) Max.
27 1/4(69.2 cm) Min.
27 5/16(69.4 cm) Max.
A
2 (5.1 cm)
Min.
Cutout
Observe all
dimensions
and
requirements.
Cutout
Observe all
dimensions
and
requirements.
36(91.4 cm)
Typical
Countertop
Height
22(55.9 cm) Min.
Above Support
Platform
9 1/2
(24.1 cm)
Max.
25(63.5 cm)
24(61 cm)
Must
match
toekick
height
4(10.2 cm)
Typical
Toekick
3/4(1.9 cm)
Support Platform
Required