GE ZDWC240 Beverage Dispenser User Manual


 
The Problem Solver
Wine Chiller
Questions?
Use this
problem
solver!
PROBLEM POSSIBLE CAUSE
APPLIANCE Appliance may be in defrost cycle when motor does not operate for
DOES NOT OPERATE about 30 minutes.
If interior light is not on, appliance may not be plugged in at
wall outlet. Push the plug completely into the wall outlet.
The fuse is blown/circuit breaker is tripped. Replace fuse or reset
the breaker.
VIBRATION OR Adjust the leveling legs as shown in the Installation Instructions.
RATTLING (Slight
vibration is normal.)
MOTOR OPERATES Normal when appliance is first plugged in. Wait 24 hours for the
FOR LONG PERIODS appliance to completely cool down.
OR CYCLES ON AND
Often occurs when large amounts of beverages are placed in appliance.
OFF FREQUENTLY
This is normal.
Door left open or package holding door open.
Hot weather or frequent door openings. This is normal.
Temperature control set at the coldest setting.
See Temperature Control. Allow 24 hours for temperature to change.
COMPARTMENT Temperature control not set cold enough.
TOO WARM See Temperature Control. Allow 24 hours for temperature to change.
Warm weather or frequent door openings.
Door left open for long time.
Package may be holding door open.
APPLIANCE Interior needs cleaning. See Care and Cleaning.
HAS ODOR
Keep open box of baking soda in appliance; replace every 3 months.
DOOR NOT Door gasket is sticking or folding over. Apply petroleum jelly
CLOSING or paraffin wax to the face of the gasket.
PROPERLY
The door is hitting an internal component inside the appliance.
Adjust interior components to prevent interference.
MOISTURE FORMS Not unusual during periods of high humidity. If bothersome,
ON OUTSIDE OF wipe surface dry; otherwise, moisture will evaporate in time.
APPLIANCE
Door left open or package holding door open.
FROST OR MOISTURE Too frequent or too long door openings.
COLLECTS INSIDE
In humid weather, air carries moisture into appliance when door
is opened. Unit will dissipate moisture in time. If bothersome,
wipe surface dry.
Temperature control set at coldest setting.
INTERIOR LIGHT No power at outlet.
DOES NOT WORK
Light bulb needs replacing. See Care and Cleaning.
15