Installation Preparation
WARNING: Disconnect electrical
power from unit before beginning remote control
installation. Failure to do so could result in personal
injury or damage to the electrical controls.
REMOTE LOCATION FOR CONTROL
NOTE: The hood is only certified for use with the
supplied 30-ft. length of wire.
The control can be removed from the hood and
installed in a backsplash or countertop.
A cover plate is provided to cover the opening in
the hood when the control is removed.
A 30-ft. length of 4-wire cord is supplied to
accommodate most installations. Because only
30-ft. of cord is provided, careful consideration
must be given to the location of the remotely
mounted control.
The 30-ft. cord is supplied with a connector/
converter on one end. DO NOT REMOVE the
connector/converter from the 30-ft. cord. Failure
to use the connector/converter with the shorter
cord will prevent proper operation of the control.
NOTE: Not for telecommunication (telephone)
network.
The cord must be routed through the holes in the
insert sleeve, and the rubber grommets put into
place around the cord.
NOTE: On the ZVC30 and ZVC36 models, the cord
needs to be routed through the holes in the insert
sleeve before the damper plate is installed.
Route the cord through the conduit to reach the
installation location of the control.
1-11/16
3-11/16
Control cutout
REMOTE MOUNTING OF THE CONTROL – WIRED
Main
PCB
Long cord
Display board
Connector/
converter
Short cord
Remotely Mounted Control—Wall or Countertop Installation