Installation
Component Cooking Surfaces
9
Step
Connect
“
Halogen/Radiant, updraft grill, downdraft grill and
electn”cal
downdraft vent component:
3-Conductor Branch Circu]t
Branch Circuit
Cooktop
Electrical
P
owe?-
requirements
.3-Conductor
Red Red
+120V AC
White or
Gray
White
Neutral
Bare or
Green
Black Black
-120VAC
Branch Circuit:
\
J
Lhagram 56.1
“ Connect red lead to branch circuit red lead.
“ Connect black lead to branch circuit black lead.
o Connect bare or green conductor and white lead* of
cooktop to branch circuit neutral lead, which is white
or gray.
4-Conductor Branch Clrcuh
Branch C[rcuit
Cooktop
Red Red
+120V AC
White or
I
Neutral
Gray
White
-120VAC :
Black
Black
4Conductor
Bare or
Bare or
GND
Green
Green
Branch Circuit:
1
Llagram 56.2
“ Connect red lead to branch circuit red lead.
- Connect black lead to branch circuit black lead.
. Break connection between cooktop white lead to bare
The frames of these appliances are grounded to neutral.
or green conductor.
. Connect cooktop white lead* to branch circuit neutral
* Updraft grill has no white neutral wire. Connect only
lead, which is white or gray.
black, red and bare wires as shown. Downdraft vent
“ Ground unit by connecting bare conductor of cooktop
has no red wire. Attach white, green and black wires
to branch circuit bare or green lead (ground lead).
as shown.
,Model #
ZGW124
ZGW125
ZEW145T
ZEW145T
ZEW154
ZEW155
ZEW164
ZEWI 65
ZEW175
Voltage
120
120
208
240
208
240
208
240
120
Frequency
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
AMPS
1.0
1.0
11.0
12.7
8.4
7.3
15.3
13.5
1.8
Kw