Grindmaster P300E Coffeemaker User Manual


 
Wiring Diagram #091-182
T3 T3 T3 1 1 T4 A
T2 T3 T3 T4 T4 T4 B
T2 T3 T3 1 1 T1 C
T3 T3 T3 T1 T1 T4 D
T2 T3 T3 T1 T1 T4 E
T2 T3 T3 T1 T1 T2 F
NOTE: USE WIRE NUT FOR 1 - 1 CONNECTION
5000 WATT / 240V HEATERS
* SEPARATE 120V REQUIRED FOR CONTROLS (3 AMP LOAD)
2.0 KW - 120/208V - 1 PH - 3 WIRE - 9 AMPS
2.5 KW - 120/240V - 1 PH - 3 WIRE - 11 AMPS
4.0 KW - 120/208V - 1 PH - 3 WIRE - 18 AMPS
5.0 KW - 120/240V - 1 PH - 3 WIRE - 21 AMPS
5.5 KW - 120/208V - 1 PH - 3 WIRE - 27 AMPS
7.5 KW - 120/240V - 1 PH - 3 WIRE - 31 AMPS
7.5 KW - 120/208V - 1 PH - 3 WIRE - 38 AMPS
10.0 KW - 120/240V - 1 PH - 3 WIRE - 42 AMPS
11.5 KW - 120/208V - 1 PH - 3 WIRE - 54 AMPS
15.0 KW - 120/240V - 1 PH - 3 WIRE - 63 AMPS
11.5 KW - 120/208V - 3 PH - 4 WIRE - 31 AMPS
15.0 KW - 240V - 3 PH - 3 WIRE - 36 AMPS *
A
B
C
D
E
F
WIRE PER FIG.FOR THIS HEAT AND ELECTRIC SERVICE
* FOR 3 PHASE WIRING
1. MOVE WIRE 6 FROM L1 TO L3
2. CONNECT HEATER ACCORDING TO FIG.F
ON CHART
3. FIG. F FOR 3 PH ONLY
WIRES 5 6 7 8 ARE 8 AWG, 105°C
1 2 3 4 ARE 10 AWG, 105°C
A
Page 32